Guest mode. You can read posts without signing up. Comments, ratings, job contacts and your own posts open after you sign up and accept the rules. What is Kommit →

Reset

2 posts tagged #монтаж: articles, how-tos, projects and jobs from the portal's IT professionals.

Редакция КоммитРедакция портала
commit 567e00b · 19 days ago

🌐 Machine-translated from Russian. Show original

In this part:

Cable part

LineCableLimitations
Reader → controller (Wiegand)a multi-core signal cable, better shieldedusually up to 100–150 m, more precisely according to
Controller → controller (RS-485, OSDP)twisted pairup to 1200 m according to line
Controller → networktwisted pair Cat5e/6up to 100 m to switch
Power supply to the lockcable by the lock current and line lengthconsider voltage drop
  • Signal lines are separate from power lines.
  • Cables in the door and door frame — through the cable junction (flexible transition), otherwise they will wear out.
  • Marking each cable on both sides and a cable log.

Diet

  • The power supply with battery is calculated based on the sum of currents: controller + readers + locks (the electromagnetic lock has constant current while the door is closed).
  • Battery life depends on the site's requirements (often several hours).
  • Separate power supply for the locks and electronics — interference from the locks does not knock down the controller.

Installing locks

  • The electromagnetic lock is placed on the door frame, the counter bar on the door; the surfaces must fit tightly, otherwise the holding force drops sharply.
  • Electromechanical cuts into the door; check compatibility with the thickness and material of the door.
  • A close close is mandatory — without it, the door does not close completely.
  • The door opening sensor allows you to track "door is held open" and break-in.
Read more
Comments 00 участников · 0 гостей🔒 Rate and discuss after signing up
Редакция КоммитРедакция портала
commit b981c89 · 19 days ago

🌐 Machine-translated from Russian. Show original

In this part:

Cable

  • For IP cameras — twisted pair of category 5e or 6, copper (not CCA — copper-plated aluminum holds PoE worse and breaks).
  • Street — cable for outdoor installation (black sheath, UV resistant), in corrugated or piped.
  • The maximum Ethernet segment length is 100 m from the switch to the camera. Next is the intermediate switch, PoE extender, or optics.
  • Lay with a margin of 0.5–1 m near the chamber and the cabinet, label both ends of the cable with the camera number.
  • Do not run low-current cables in the same tray as power cables without a separator.

PoE: Power over the grid

| Standard | Power per port | What | for
| --- | --- | --- |
| 802.3af (PoE) | up to 15.4 W | most dome and cylindrical chambers |
| 802.3at (PoE+) | up to 30W | camera with powerful backlighting, heating, motorized lens, |
| 802.3bt (PoE++) | 60W and above | rotating PTZ cameras with |

Calculate the switch's PoE budget: the total consumption of all cameras should be less than the total PoE power of the switch, with a margin of 20–30%. Check the camera consumption in the specifications — with IR illumination enabled, it is higher.

Recorders with built-in PoE ports are convenient for small systems: the camera connects directly to the recorder via a single cable.

Height and installation point

Read more