ACS, part 1: how the system works — cards, readers, controllers, locks, and interfaces
🌐 Machine-translated from Russian. Show original
In this part:
What the ACS consists of#
- Identifier — what a person presents: card, key fob, phone, fingerprint, face, PIN code.
- The reader reads the identifier and passes the code to the controller.
- The controller makes the decision 'to let it in or not' based on its own rules and base.
- Actuators include a lock, turnstile, barrier, gate.
- Sensors and buttons — exit button, door open sensor, emergency unlock.
- Power supply — power supply with battery.
- Software — management of users, rights, event log (in network systems).
Identifiers: what to choose#
| Type | Frequency | Copy protection | Where | occurs
| --- | --- | --- | --- |
| EM-Marine and analogs | 125 kHz | very low — copied by cheap copiers | old and budget systems, intercoms, |
| Mifare Classic | 13.56 MHz | low — known vulnerabilities, copied | many active systems |
| Mifare Plus / DESFire EV2/EV3 | 13.56 MHz | high — cryptographic protection | new systems with security requirements |
| Mobile key (BLE/NFC) | — | depends on the implementation of | modern enterprise systems |
| Biometrics (face, fingerprint) | — | is not transmitted or lost | office entry, time tracking, |
Tip: for the new system, choose secure cards (DESFire or equivalent) or mobile keys. 125 kHz cards are copied in seconds — this is not protection, but a pass "for the honest."
Readers and interfaces#
- Wiegand (26/34 bit) is the most common interface between the reader and the controller. Simple but does not encrypt data: the card code can be intercepted on the line.
- OSDP is a modern RS-485 protocol: two-way communication, reader state monitoring, encryption (OSDP Secure Channel). Preferred for new objects.
- The reader with built-in keyboard allows two-factor input: card + PIN.
Castles#
| Type | How it works | Pros | Cons |
|---|---|---|---|
| The electromagnetic | holds the door with a magnet live | is reliable, simple, | open without power; a quality battery unit with a |
| The electromechanical | the bolt or latch is opened by a pulse | closed without power | installation |
| Electromechanical latch (response bar) | opens the latch of a regular lock | cheaply, is inserted into an existing door, | has lower burglary resistance |
Important concept:
- Fail-safe (normally open) — opens when power goes out. Mandatory on evacuation routes.
- Fail-secure — remains closed in case of power failure. For server rooms, cash registers, warehouses — but not on evacuation routes.
Offline or networked#
- Autonomous: the door controller stores the card list itself, programmable by master card or keyboard. No event log or minimal. Suitable for one or two doors.
- Network: controllers are connected to the server, rights and log are in the software, changes are applied to all doors at once. Needed for multiple doors, employees with shifts, and log requirements.