Who is it suitable for#
Small office, store, warehouse, server room: one or two doors, up to several dozen employees, no or minimal passage log required.
Set#
- A standalone controller with a reader (often in the same case as the keyboard) or separate controller and reader.
- Lock: electromagnetic for glass and light doors, electromechanical latch for regular doors.
- Exit button from inside.
- 12V power supply with battery — lock and controller operate during power outages.
- Closer — without it, the door will remain slightly open and the lock won't work.
- Cards or key fobs (preferably 13.56 MHz, see part 1.
Many manufacturers produce such kits — from budget brands to ZKTeco, Hikvision, and Dahua.
Wiring diagram#
[Считыватель/клавиатура] ── контроллер ── реле ──> [Замок]
│
[Кнопка выхода] [Датчик двери]
│
[Блок питания 12 В + АКБ]
- The lock is powered through a controller relay and must have a protective diode (often included) — otherwise, voltage surges when the electromagnet is disconnected will damage the controller.
- The output button connects to the controller input, not directly into the lock circuit — this is how the controller locks the output.
- On evacuation routes, there is an emergency release button that cuts the lock power directly.
Programming#
Typical order for standalone controllers (specific codes are in the model manual):
- Enter programming mode with master code or master card and change the factory master code.
- Add cards: bring them in turn or enter numbers from the keyboard.
- Set the lock opening time (usually 3–5 seconds).
- Check the entry, button exit, and operation when the power is disconnected (on the battery).
Card accounting#
Even in an offline system, keep a table: card number → employee → date of issue. When dismissed, the card must be removed from the controller, not just taken away: the employee could have made a copy.
Limitations#
- No remote control: you can only add or remove a card at the door.
- The pass log is missing or hard to obtain.
- Scaling to 3+ doors turns into bypassing all controllers with each change.
When these restrictions start to get in the way, it's time to switch to a network system.