Video surveillance, part 3: installation — cable, PoE, switches, installation height, and power
🌐 Machine-translated from Russian. Show original
In this part:
Cable#
- For IP cameras — twisted pair of category 5e or 6, copper (not CCA — copper-plated aluminum holds PoE worse and breaks).
- Street — cable for outdoor installation (black sheath, UV resistant), in corrugated or piped.
- The maximum Ethernet segment length is 100 m from the switch to the camera. Next is the intermediate switch, PoE extender, or optics.
- Lay with a margin of 0.5–1 m near the chamber and the cabinet, label both ends of the cable with the camera number.
- Do not run low-current cables in the same tray as power cables without a separator.
PoE: Power over the grid#
| Standard | Power per port | What | for
| --- | --- | --- |
| 802.3af (PoE) | up to 15.4 W | most dome and cylindrical chambers |
| 802.3at (PoE+) | up to 30W | camera with powerful backlighting, heating, motorized lens, |
| 802.3bt (PoE++) | 60W and above | rotating PTZ cameras with |
Calculate the switch's PoE budget: the total consumption of all cameras should be less than the total PoE power of the switch, with a margin of 20–30%. Check the camera consumption in the specifications — with IR illumination enabled, it is higher.
Recorders with built-in PoE ports are convenient for small systems: the camera connects directly to the recorder via a single cable.
Height and installation point#
- 2.5–3 m — optimal for faces: higher — the camera sees the crowns, lower — easy to damage.
- Point the camera inward toward the entrance, not outside: this way, there is no illumination from the doorway.
- Consider where the light sources will be at night and whether IR reflections from glass or walls near the camera will hit the frame.
- For outdoor use — canopies and canopies from direct sunlight and precipitation.
Camera installation#
- Mark the space according to the template from the set.
- Use the manufacturer's mounting box — it hides the connector and cable reserve.
- Seal the connector outdoors: protective cap included, heat shrink, sealed water. Moisture in the connector is a common cause of failure.
- Connect the cable, check the image until fully fixed, and only then set the angle.
Cabinet and recorder#
- The recorder, switches, and patch panel are in a ventilated cabinet .
- UPS for the recorder, switches, and router: recording is not interrupted during brief outages, disks are not damaged.
- Ground the cabinet, place lightning protection devices near the camera and the switch on outdoor lines.
Post-installation inspection#
- Each camera is visible in the dashcam, and the number on the cable matches the number in the system.
- Check the image day and night — night checks often detect glare and reflections.
- Write down IP addresses, logins, and installation location in the system passport.
Next is the setup: Hikvision.
Comments · 0
No comments yet.Sign in to comment, rate and see all comments.